| Ex d | Flameproofolder | Gb | — | IEC 60079-1 | Anything that could ignite the gas sits inside a strong enclosure. If gas gets in and ignites, the enclosure contains the explosion and the flame paths cool the escaping gas. |
| Ex da | Flameproof | Ga | — | IEC 60079-1 | Flameproof enclosure at the highest level, for small items such as catalytic sensors that may go into Zone 0. |
| Ex db | Flameproof | Gb | — | IEC 60079-1 | Anything that could ignite the gas sits inside a strong enclosure. If gas gets in and ignites, the enclosure contains the explosion and the flame paths cool the escaping gas. |
| Ex dc | Flameproof | Gc | — | IEC 60079-1 | Flameproof enclosure for Zone 2, typically for switching contacts. |
| Ex e | Increased safetyolder | Gb | — | IEC 60079-7 | No arcs, sparks or hot surfaces in normal use, with extra safeguards on terminals, clearances, creepage distances and temperature rise. |
| Ex eb | Increased safety | Gb | — | IEC 60079-7 | No arcs, sparks or hot surfaces in normal use or in expected faults, with extra safeguards on terminals, clearances, creepage distances and temperature rise. The usual protection for Ex e terminal and junction boxes. |
| Ex ec | Increased safety | Gc | — | IEC 60079-7 | Increased safety for Zone 2. Replaced Ex nA (non-sparking) in 2015. |
| Ex ia | Intrinsic safety | Ga | Da | IEC 60079-11 | The energy in the circuit is limited so that no spark or hot surface can ignite the atmosphere, even with two faults at once. |
| Ex ib | Intrinsic safety | Gb | Db | IEC 60079-11 | The energy in the circuit is limited so that no spark or hot surface can ignite the atmosphere, even with one fault. |
| Ex ic | Intrinsic safety | Gc | Dc | IEC 60079-11 | The energy in the circuit is limited so that no spark or hot surface can ignite the atmosphere in normal operation. Replaced Ex nL. |
| Ex m | Encapsulationolder | Gb | Db | IEC 60079-18 | Parts that could ignite the atmosphere are sealed in a compound such as resin, so the atmosphere can’t reach them. |
| Ex ma | Encapsulation | Ga | Da | IEC 60079-18 | Parts that could ignite the atmosphere are sealed in a compound such as resin, so the atmosphere can’t reach them, even with two faults. |
| Ex mb | Encapsulation | Gb | Db | IEC 60079-18 | Parts that could ignite the atmosphere are sealed in a compound such as resin, so the atmosphere can’t reach them, even with one fault. |
| Ex mc | Encapsulation | Gc | Dc | IEC 60079-18 | Encapsulation for Zone 2 and Zone 22. |
| Ex o | Liquid immersionolder | Gb | — | IEC 60079-6 | Parts that could ignite the gas are immersed in a protective liquid such as oil. |
| Ex ob | Liquid immersion | Gb | — | IEC 60079-6 | Parts that could ignite the gas are immersed in a protective liquid such as oil. |
| Ex oc | Liquid immersion | Gc | — | IEC 60079-6 | Liquid immersion for Zone 2. |
| Ex p | Pressurisationolder | Gb | Db | IEC 60079-2 | The enclosure is kept at a higher pressure than outside with clean air or inert gas, so the atmosphere can’t get in. |
| Ex px | Pressurisationolder | Gb | Db | IEC 60079-2 | Pressurised enclosure that switches the equipment off if pressure is lost. |
| Ex py | Pressurisationolder | Gb | Db | IEC 60079-2 | Pressurised enclosure for equipment that is itself suitable for Zone 2. |
| Ex pz | Pressurisationolder | Gc | Dc | IEC 60079-2 | Pressurised enclosure for Zone 2 with an alarm on loss of pressure. |
| Ex pxb | Pressurisation | Gb | Db | IEC 60079-2 | Pressurised enclosure that switches the equipment off if pressure is lost. |
| Ex pyb | Pressurisation | Gb | Db | IEC 60079-2 | Pressurised enclosure for equipment that is itself suitable for Zone 2. |
| Ex pzc | Pressurisation | Gc | Dc | IEC 60079-2 | Pressurised enclosure for Zone 2 with an alarm on loss of pressure. |
| Ex q | Powder fillingolder | Gb | — | IEC 60079-5 | Parts that could ignite the gas are surrounded by a fine powder such as quartz sand. |
| Ex qb | Powder filling | Gb | — | IEC 60079-5 | Parts that could ignite the gas are surrounded by a fine powder such as quartz sand. |
| Ex nA | Non-sparkingolder | Gc | — | IEC 60079-15 | Equipment that doesn’t spark in normal use. Replaced by Ex ec in 2015. |
| Ex nC | Enclosed break / sealed device | Gc | — | IEC 60079-15 | Sparking contacts sealed so gas can’t reach them. Zone 2 only. |
| Ex nR | Restricted breathing | Gc | — | IEC 60079-15 | The enclosure is sealed so tightly that gas would get in too slowly to build up an explosive mixture. It needs a test port so the seal can be checked. Zone 2 gas only. |
| Ex nL | Energy limitedolder | Gc | — | IEC 60079-15 | Energy-limited circuits for Zone 2. Replaced by Ex ic. |
| Ex s | Special protectionolder | Gb | Db | IEC 60079-33 | Protection that isn’t covered by the other standards, assessed case by case. |
| Ex sa | Special protection | Ga | Da | IEC 60079-33 | Protection that isn’t covered by the other standards, assessed case by case. |
| Ex sb | Special protection | Gb | Db | IEC 60079-33 | Protection that isn’t covered by the other standards, assessed case by case. |
| Ex sc | Special protection | Gc | Dc | IEC 60079-33 | Protection that isn’t covered by the other standards, assessed case by case. |
| Ex t | Dust protection by enclosureolder | — | Db | IEC 60079-31 | A dust-tight enclosure (IP6X) whose outside surface stays below a stated temperature. |
| Ex ta | Dust protection by enclosure | — | Da | IEC 60079-31 | A dust-tight enclosure whose outside surface stays below a stated temperature, at the highest level of protection. |
| Ex tb | Dust protection by enclosure | — | Db | IEC 60079-31 | A dust-tight enclosure (IP6X) whose outside surface stays below a stated temperature. The usual dust protection for terminal boxes and control stations. |
| Ex tc | Dust protection by enclosure | — | Dc | IEC 60079-31 | Enclosure protection for Zone 22 (IP5X for non-conductive dust, IP6X for conductive dust). |
| Ex op is | Optical radiation, inherently safe | — | — | IEC 60079-28 | Light from lasers or LEDs is too weak to ignite the atmosphere. |
| Ex op pr | Optical radiation, protected | — | — | IEC 60079-28 | Light from lasers or LEDs is kept inside fibre or cable so it can’t escape. |
| Ex op sh | Optical radiation, interlocked | — | — | IEC 60079-28 | The light source shuts off if the beam escapes, for example if a fibre breaks. |
| Ex h | Non-electrical equipment | — | — | ISO 80079-36 / -37 | Mechanical equipment such as pumps, gearboxes and couplings, assessed for hot surfaces and mechanical sparks. The EPL in the marking gives the zones. |
| Ex c | Constructional safety (non-electrical)older | — | — | EN 13463-5 | Older marking for non-electrical equipment. Replaced by Ex h. |
| Ex b | Control of ignition sources (non-electrical)older | — | — | EN 13463-6 | Older marking for non-electrical equipment. Replaced by Ex h. |
| Ex k | Liquid immersion (non-electrical)older | — | — | EN 13463-8 | Older marking for non-electrical equipment. Replaced by Ex h. |
| Ex fr | Flow-restricting enclosure (non-electrical)older | — | — | EN 13463-2 | Older marking for non-electrical equipment. Replaced by Ex h. |
| Ex g | Inherent safety (non-electrical)older | — | — | EN 13463-1 | Older marking for non-electrical equipment. Replaced by Ex h. |