A process-plant customer needed a terminal box for intrinsically safe circuits that would be installed in both gas and dust zones, with condensation a known problem on site. They wanted it delivered complete, so it could be fixed to the wall and terminated straight away.
The brief
- 316L stainless steel
- Full ATEX certification for gas and dust
- Terminals, DIN rail, gland cut-outs, blanking plugs, earth stud and labels supplied fitted
- A certified breather drain to manage condensation
What we built
One of our iTB terminal boxes, 400 x 400 x 200mm in 1.2mm 316L with a brushed finish. A right-hand hinged lift-off door gives full access inside, with four bolt-on wall lugs and an M10 internal/external earth stud.
Inside, 40 blue WDU 2.5mm² terminals run in one vertical bank between two lengths of blue 80 x 40mm slotted trunking, with a horizontal earth bar and tagged terminals ready for site termination. The galvanised steel mounting plate sits on four M6 x 25mm rear studs. The base has M20 and M25 entries, certified stopping plugs in the unused entries and a certified stainless steel breather drain.
Every unit carries an engraved stainless steel tag and the intrinsically safe warning label.
Why Ex ia and why blue
Ex ia protects by limiting the energy in the circuit so it cannot ignite gas, even with two faults. Category 1 (Ga) means the box can serve circuits in Zone 0, the most hazardous gas zone. Blue terminals and trunking are the usual way to mark intrinsically safe wiring so it is kept apart from other circuits. Our Ex ia guide covers the rules in more detail.
A breather drain lets the enclosure equalise pressure and drain condensed water without compromising the IP66 and Ex tb seal. Without one, temperature cycling can draw in moist air that condenses on terminals.
Got a similar requirement? Send us your drawing or spec, or call +44 1233 801 890.