A hazardous-area systems integrator had an urgent end-of-year need for an Ex-certified enclosure that would form one half of a two-box Ex assembly. Turnaround mattered as much as build quality.
What we built
- A 327 x 1250 x 403mm enclosure in 2mm 316L stainless steel with a brushed finish
- A bolt-down lid (no hinges) fixed around the full perimeter, with nutserts and a gasket so it assembles cleanly to the partner Ex e enclosure
- 10 x M6 x 25mm studs welded into the rear face for a galvanised steel mounting plate, without piercing the outer skin
- Two welded lugs on the rear for skid or wall mounting
- Entries machined in the base (1 x 20.5mm, 3 x 25.5mm, 2 x 32.5mm, 2 x 32.94mm and 8 x 3.25mm) plus one 25.5mm entry in the left side, ready for the customer's Ex d e pushbutton and mushroom-head stop button on the lid
- An 80 x 40mm recessed label carrier in the lid for the certification plate
From prototype to batch
The order ran as one prototype in December, then a batch of ten in January. That made dimensional repeatability and consistent certification across the run critical.
The enclosure is certified as an Ex component (the "U" certificate), which the integrator then incorporates into their own certified assembly.
What the marking means. Ex eb is increased safety: the enclosure and terminals are built so that no arc, spark or hot surface can occur in normal use, rather than containing an explosion. Ex tb means the enclosure keeps dust out tightly enough for combustible-dust areas, and IP66 confirms it is dust-tight and resists powerful water jets. Category 2 (Gb/Db) equipment is suitable for Zones 1 and 2 (gas) and Zones 21 and 22 (dust). See our Ex eb guide and zone classification guide.
Got a similar requirement? Send us your drawing or spec, or call +44 1233 801 890.