← Case Studies
Case Study June 2026

Pre-wired ATEX engine interface enclosure with 99 terminals

Open stainless steel terminal enclosure with three vertical banks of beige terminals

A company that makes explosion protection systems for engines and vehicles working in hazardous areas needed an engine interface enclosure: a fully populated terminal box for equipment operating in potentially explosive gas and dust atmospheres.

The brief

  • Certification to II 2 G Ex eb IIC T6 Gb and II 2 D Ex tb IIIC T85°C Db, IP66, for −50°C to +40°C ambient
  • 2mm 316L stainless steel for corrosion resistance
  • A compact 400 x 300 x 150mm footprint for a tight installation
  • 76 x WDU 2.5mm² and 12 x WDU 10mm² terminals plus 11 earth terminals, in three vertical banks, cross-connected exactly to their drawing
  • Terminals tagged to the customer's own numbering (1–88, plus dedicated earth points)
  • Four gland plates drilled with 20.5mm and 25.5mm holes across the left, bottom and right faces

What we built

A brushed 316L enclosure with a left-hand hinged lift-off door captivated by a removable locking nut, M6 studs welded to the rear for the galvanised mounting plate, and an M10 internal/external earth stud. Each removable gland plate has its own internal M6 earth stud, which keeps earth continuity when a plate is taken off.

The DIN rail layout, end stops, 2-, 3- and 4-way WQV jumper bars and printed marker strips were all built, wired and tagged in-house to the customer's drawing. It was delivered as a drop-in certified assembly: one part number, fully documented, ready to install.

What the marking means. Ex eb is increased safety: the enclosure and terminals are built so that no arc, spark or hot surface can occur in normal use, rather than containing an explosion. Ex tb means the enclosure keeps dust out tightly enough for combustible-dust areas, and IP66 confirms it is dust-tight and resists powerful water jets. Category 2 (Gb/Db) equipment is suitable for Zones 1 and 2 (gas) and Zones 21 and 22 (dust). See our Ex eb guide and zone classification guide.

The customer specified Zone 2/22 use; the Category 2 certification also covers Zone 1/21, giving headroom if the area classification changes.

Closed stainless steel engine interface enclosure with cable entries on the side

Got a similar requirement? Send us your drawing or spec, or call +44 1233 801 890.